- solid state relay
- Circuit Board Solid State Relay
- Single phase solid state relay
- Industrial Solid State Relays
- Three-phase solid state relay
- Three-phase forward and reverse solid state relay
- Rail type three-phase solid state relay
- Industrial grade solid state relay module
- Tension controller
- Intelligent voltage regulation module
- Single and three-phase silicon controlled trigger
- heat sink
- Semiconductor module, rectifier bridge series
- time relay
- Digital display counter
- water level controller
- timer
- switching power supply
- S series switching power supply
- MS series switching power supply
- LRS series switching power supply
- D, T, Q multi-group series switching power supplies
- DR rail series switching power supply
- NDR rail series switching power supply
- MDR rail series switching power supply
- HDR rail series switching power supply
- FY rainproof series switching power supply
- FS rainproof series switching power supply
- Foot switch
- Fan water pump controller
DR-30-24
Model meaning
?
DR-30-24 | Model meaning |
DR? | Switching power supply development code: DR: Guide rail basic type MDR: Guide rail plastic case type NDR: Guide rail small size type HDR: Guide rail economical plastic case type |
30 | Rated power: 15W 30W 45W 60W 75W 100W 120W 150W 240W 480W |
twenty four | Output DC voltage: 5V 12V 15V 24V 36V 48V |
?
Features
?
High performance/price ratio
Pressure resistant and high efficiency
Quality is close to that of European and American products
Input AC power for global use
Small size, light weight, easy to install
The output has multiple protections for overcurrent, overvoltage and short circuit.
Can output 1-4 different voltages at the same time
?
Technical parameters
?
model | DR-30-5 | DR-30-12 | DR-30-24 | |
? ? ? output ? ? ? ? ? | DC output voltage | 5V | 12V | 24V |
Output voltage tolerance | ±2% | ±1% | ±1% | |
Rated output current | 3A | 2A | 1.5A | |
Output current range | 0~3A | 0~2A | 0~1.5A | |
Output power | 15W | 24W | 36W | |
Ripple and noise | 80mvp-p | 100mvp-p | 150mvp-p | |
Voltage adjustable range | -9%~+10% | ±10% | ±10% | |
Input voltage range | 90~264VAC,127~373VDC | |||
frequency | 47~63HZ | |||
enter ? ? ? | AC input current | 0.88A/110VAC,0.48A/220VAC | ||
efficiency | 75% | 81% | 83% | |
Inrush current | Cold start current 15A/110VAC, 30A/220VAC | |||
Leakage current |
| |||
Save protect special sex | Overload protection | Overload protection starts at 105%~150% of rated output power | ||
Protection mode: hiccup mode, automatically recovers after abnormal load conditions are removed | ||||
Overvoltage protection | 6.8~8.2V | 15.6~17.8V | 30.6~33.2V | |
Protection method: turn off the output and clamp it with a Zener diode | ||||
environment | Working temperature, humidity | -20℃~+50℃,20%~90%RH | ||
Storage temperature and humidity | -20℃~+85℃, 10%~95%RH non-condensing | |||
Earthquake resistance | 10~500HZ, 2G 10min/1 cycle, duration 60 minutes, each axis | |||
Safety | Pressure resistance | Input and output room: 1.5KVAC | ||
Insulation resistance | Input and output room: 100M ohms/500VDC | |||
standard | safety standards | Comply with UL1012 | ||
EMC standards | Comply with EN55022, CLASSA | |||
other | size | 78*93*56mm (L*W*H) | ||
Weight/Packaging | 0.27kg/48pcs/14kg/0.03 cubic meters | |||
Remark | Unless otherwise specified, all parameters are measured at 230VAC voltage input, rated load and 25°C. | |||
Ripple and noise voltages were measured on a 20MHZ bandwidth oscilloscope with 0.1μ and 47μ capacitors added to the ends of 12 feet of twisted pair cable. | ||||
Tolerance is the sum of voltage setting error, voltage regulation, and current regulation. |
?