- solid state relay
- Circuit Board Solid State Relay
- Single phase solid state relay
- Industrial Solid State Relays
- Three-phase solid state relay
- Three-phase forward and reverse solid state relay
- Rail type three-phase solid state relay
- Industrial grade solid state relay module
- Tension controller
- Intelligent voltage regulation module
- Single and three-phase silicon controlled trigger
- heat sink
- Semiconductor module, rectifier bridge series
- time relay
- Digital display counter
- water level controller
- timer
- switching power supply
- S series switching power supply
- MS series switching power supply
- LRS series switching power supply
- D, T, Q multi-group series switching power supply
- DR rail series switching power supply
- NDR rail series switching power supply
- MDR rail series switching power supply
- HDR rail series switching power supply
- FY rainproof series switching power supply
- FS rainproof series switching power supply
- Foot switch
- Fan water pump controller
LRS-200
Model meaning
?
LRS-200-24 | Model meaning |
LRS | Switching power supply development code: S: Basic type MS: Small size type LRS: Ultra-thin type |
200 | Rated power: 15W 25W 35W 50W 60W 75W 100W 120W 150W 200W 250W 350W 400W 500W 600W 1000W 1500W 2000W |
twenty four | Output DC voltage: 5V 12V 15V 24V 36V 48V |
?
Features
?
High performance/price ratio
Pressure resistant and high efficiency
Quality is close to that of European and American products
Input AC power for global use
Small size, light weight, easy to install
The output has multiple protections for overcurrent, overvoltage and short circuit.
Can output 1-4 different voltages at the same time
?
Technical parameters
?
model performance | LRS-200-12 | LRS-200-24 | LRS-200-36 | LRS-200-48 |
DC output voltage, current | 12V? 17A | 24V? 8.8A | 36V 5.9A | 48V 4.4A |
Ripple and noise | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p |
Incoming line stability | ±0.5% | 0.50% | 0.50% | ±0.5% |
Load stability | ±1% | ±0.5% | ±0.5% | ±0.5% |
efficiency | 87% | 88% | 90% | 91% |
DC voltage adjustable range | ±10% | ±10% | ±10% | ±10% |
Input voltage range | 90-132VAC 180-264VAC selected by switch | |||
Inrush current | Cold start current 60A/110V~230V | |||
Overload protection | 105%--130% cut off output, reset: automatic recovery | |||
Overvoltage protection | 115%~145% protection mode: turn off the output voltage and restart the output | |||
Start, rise and hold time | 1300ms 50ms/230VAC? 1300ms 50ms/115VAC | |||
Pressure resistance | I/P-O/P:3KvAC, 1/P-FG:2KVAC,O/P-FG:0.5KvAC | |||
Isolation resistor | I/P-O/P,I/P-FG,O/P-FG:500VDC100MΩ | |||
Working temperature, humidity | ~-10°C~+60°C,20%~90%RH | |||
safety standards | Comply with GB4943 | |||
EMC standards | Comply with GB9254, EN55022 level A | |||
weight | 0.55Kg |
?
?
Dimensional drawing
?
?
?
?
Wiring location
?
Port 1.2.3: DC output +V
?
Port 4.5.6: DC output -V
?
Port 7: Ground
?
Port 8.9: AC input
?