- solid state relay
- Circuit Board Solid State Relay
- Single phase solid state relay
- Industrial Solid State Relays
- Three-phase solid state relay
- Three-phase forward and reverse solid state relay
- Rail type three-phase solid state relay
- Industrial grade solid state relay module
- Tension controller
- Intelligent voltage regulation module
- Single and three-phase silicon controlled trigger
- heat sink
- Semiconductor module, rectifier bridge series
- time relay
- Digital display counter
- water level controller
- timer
- switching power supply
- S series switching power supply
- MS series switching power supply
- LRS series switching power supply
- D, T, Q multi-group series switching power supply
- DR rail series switching power supply
- NDR rail series switching power supply
- MDR rail series switching power supply
- HDR rail series switching power supply
- FY rainproof series switching power supply
- FS rainproof series switching power supply
- Foot switch
- Fan water pump controller
LRS-75
Model meaning
?
LRS-75-24 | Model meaning |
LRS | Switching power supply development code: S: Basic type MS: Small size type LRS: Ultra-thin type |
75 | Rated power: 15W 25W 35W 50W 60W 75W 100W 120W 150W 200W 250W 350W 400W 500W 600W 1000W 1500W 2000W |
twenty four | Output DC voltage: 5V 12V 15V 24V 36V 48V |
?
Features
?
High performance/price ratio
Pressure resistant and high efficiency
Quality is close to that of European and American products
Input AC power for global use
Small size, light weight, easy to install
The output has multiple protections for overcurrent, overvoltage and short circuit.
Can output 1-4 different voltages at the same time
?
Technical parameters
?
model | LRS-75-5 | LRS-75-12 | LRS-75-15 | LRS-75-24 | LRS-75-36 | LRS-75-48 | |
output | DC voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Rated current | 14A | 6A | 5A | 3.2A | 2.1A | 1.6A | |
Current range | 0~14A | 0~6A | 0~5A | 0~3.2A | 0~2.1A | 0~1.6A | |
Rated power | 70W | 72W | 75W | 76.8W | 75.6W | 76.8W | |
Ripple and Noise (Max) | 100mVp-p | 120mVp-P | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
enter | Voltage adjustment range/ | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% |
Voltage accuracy | ±3% | ±2% | ±1% | ±1% | ±1% | ±1% | |
Linear adjustment rate | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
load regulation | ±2% | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Start-up and rise time | 800ms30ms, 30ms/230VAC (at full load) 90~264VAC, 127~373VDC (can withstand 300VAC surge input for 5 seconds without damage] | ||||||
voltage range | 47~63Hz | ||||||
frequency range | 1.4A/115V,0.85A/230VAC | ||||||
efficiency | 86% | 88% | 89% | 90% | 91% | 91% | |
Inrush current | Cold start current 50A/230VAC | ||||||
Leakage current |
| ||||||
Protect | overload | Overload protection starts at 110%~150% of rated output power | |||||
Protection mode: Isolation mode, normal output can be automatically restored after abnormal conditions are removed | |||||||
Overvoltage | Overvoltage protection starts at 115%-135% of rated output voltage | ||||||
Protection mode: Turn off the output, and the normal output can be automatically restored after the abnormal conditions are removed. | |||||||
environment | working temperature | ~-30C~+70C (please refer to the load derating curve) | |||||
Working humidity | 20%-90%RH. No condensation | ||||||
Storage temperature and humidity | ~-40C-+85C;10%-95%RH non-condensing | ||||||
Earthquake resistance | 10~500Hz, 3G 10min./1 cycle, duration 60 minutes, each axis | ||||||
Safety regulations and electromagnetic compatibility | Pressure resistance | Input and output room (WP-O/P): 3KVAC Input and ground (I/P-FG): 2KVAC Output and ground (O/P-FG): 0.5KVAC | |||||
Insulation resistance | Between input and output (P~0/P), input and ground (P~FG), output and ground (O/P~FG): 100M Ohms/500VDC/25C/70%RH | ||||||
safety regulations | Comply with UL60950-1TUVEN60950-1GB4943 | ||||||
Electromagnetic compatibility emissions | Comply with EN55022 (CISPR22) Class B, GB9254 Class BEN55014EN61000-3-23 | ||||||
Electromagnetic compatibility immunity | Comply with EN61000-4-2,3,456,8,11EN55024EN61000-6-1 | ||||||
other | size | 99*97*30mm(LWH) | |||||
? | Package | 0.28kg/00pcs/00kg/0000 cubic meters | |||||
Remark | 1. Unless otherwise specified, all parameters are measured under the conditions of 230VAC voltage input, rated load and 25C. | ||||||
2. The ripple and noise voltages are measured on a 20MHz bandwidth oscilloscope with 0.1 and 47 capacitors added to the end of a 12-inch twisted pair. | |||||||
3. Accuracy: voltage setting error, linear regulation rate and load regulation rate. | |||||||
4. Linear regulation rate measurement method; test from low voltage to high voltage under rated load. | |||||||
5. Load regulation measurement method: from 0% to 100% rated load. | |||||||
6. When the operating altitude is higher than 2000 meters (6500ft), the operating environment needs to be lowered by 5C/1000 meters. | |||||||
7. The power supply should be regarded as part of the components in the system, and electromagnetic compatibility needs to be confirmed in conjunction with the terminal equipment. |
?
Dimensional drawing
?
?