- solid state relay
- Circuit Board Solid State Relay
- Single phase solid state relay
- Industrial Solid State Relays
- Three-phase solid state relay
- Three-phase forward and reverse solid state relay
- Rail type three-phase solid state relay
- Industrial grade solid state relay module
- Tension controller
- Intelligent voltage regulation module
- Single and three-phase silicon controlled trigger
- heat sink
- Semiconductor module, rectifier bridge series
- time relay
- Digital display counter
- water level controller
- timer
- switching power supply
- S series switching power supply
- MS series switching power supply
- LRS series switching power supply
- D, T, Q multi-group series switching power supplies
- DR rail series switching power supply
- NDR rail series switching power supply
- MDR rail series switching power supply
- HDR rail series switching power supply
- FY rainproof series switching power supply
- FS rainproof series switching power supply
- Foot switch
- Fan water pump controller
MJGX-3 A4880A
Features
?
1. Bidirectional thyristor output, zero voltage on, zero current off.
2. The input signal is compatible with TTL and COMS digital logic circuits.
3. Optical isolation between input loop and output loop.
4. LED indicates working status;
5. The isolation voltage between the input terminal and the output terminal is ≥2500V.
6. A universal product with high cost performance, wide application and high reliability.
7. 100% load current aging test, passed European CE certification, international ISO9000 certification, and domestic 3C certification.
?
Model meaning
?
MJGX-3 A4880A | Model meaning |
M? | Corporate logo: M: Mingxin |
JGX | Solid state relay development code name |
-3 | 3: represents three phases |
A | Input control mode: D: DC 4-32VDC A: AC 80-250VAC |
48 | Output load voltage: 24: 240V 38:380V, 48: 480V, |
80 | Output rated current: 10A 25A 40A 60A 80A 100A 120A 150A 200A |
A | A: Output load AC value AC |
?
Product application
?
The MJGX-3 series three-phase solid state relay adopts flame-retardant engineering plastic shell, epoxy resin potting, and threaded terminal wiring. It has high structural strength, impact resistance, strong vibration resistance, and input terminal. The input end drive current is small and can be easily interfaced with computer terminals and various digital program-controlled circuits. It is widely used in petrochemical equipment, food machinery, packaging machinery, textile machinery, CNC machine tools, plastic machinery, fitness equipment, entertainment facilities and other automated controls. field.
It is especially suitable for harsh environments such as corrosion, moisture, dustproof, explosion-proof requirements, and frequent switching situations. It is an updated replacement product for AC contactor.
?
Technical parameters
?
three Mutually pay flow solid state follow electricity device | Product model classification | MJGX-3-A4860A、MJGX-3-A4880A、MJGX-3-A48100A、MJGX-3-A48120A、MJGX-3-A48150A、MJGX-3-A48200A |
Control method | AC controlled AC (AC-AC) | |
Load current | 60A、80A、100A、120A、150A、200A | |
load voltage | 480VAC | |
control voltage | AC:8-250VAC | |
control current | AC≤15mA | |
On-state leakage current | ≤10mA | |
On-state voltage reduction | ≤1.8VAC | |
Off state time | ≤10mS | |
Medium pressure resistance | 2500VAC | |
Insulation resistance | 1000MΩ/500VDC | |
ambient temperature | -30℃-+75℃ | |
Installation method | bolted | |
work instructions | LED | |
weight | 550g |
?
?
Appearance and installation dimensions/wiring diagram
Safety precautions
?
1. When the load current is higher than 10A, a radiator must be used or installed on a metal base plate with corresponding heat dissipation effect, and thermal silicone grease is applied between the solid state relay heat dissipation base plate and the mounting surface. Above 40A, a fan is used for forced cooling or water cooling.
2. When used with AC inductive loads, high transient voltages and surge currents are applied to the output end, which may cause the solid-state relay to conduct or be damaged. It is usually necessary to connect a voltage control device with a specific clamping voltage to the output end, such as Bi-wire zener diode or varistor (MOV). It is recommended that the varistor be 1.6-1.9 times the rated voltage;
3. When controlling a smaller current load close to the minimum load current, a virtual load resistor must be connected in parallel to the load to reduce the output leakage current and produce a higher residual voltage on the load.
4. In order to prevent the temperature rise of solid-state relays from exceeding the allowable value, the heat dissipation effect and installation location should be considered when designing and applying. When two or more solid-state relays are installed side by side, appropriate spacing should be left.
5. The output terminals of multiple solid-state relays must not be used in parallel in an attempt to increase the output current. However, the output terminals can be used in series to accommodate higher operating voltages.
6. When using multiple solid-state relays to share a control power supply, the input terminals can be used in series or in parallel.
7. Please use this piece with caution for capacitive loads. Please choose a solid-state relay dedicated for capacitive loads.