MJGZ-1 D2430A

1. Optical isolation between weak current part and strong current part

2. Control signal and TTL logic interface

3. The strong electric control switch is composed of thyristor and rectifier

4. LED indicates working status

5. Widely used in electrolysis, electroplating, electromagnetic vibration, electromagnetic magnets, DC power supplies, DC motors and other equipment for non-contact switch control

    Product overview

    ?

    The single three-phase rectifier solid-state relay uses high-power thyristors and rectifiers to form a rectifier circuit. The weak current part and the strong current part are optically isolated, which can convert AC into DC output with smaller weak current signal. The control signal can be interfaced with switching power supply, microcomputer and TTL logic. The product is widely used in electrolysis, electroplating, electromagnetic vibration, DC power supply, DC Motors and other equipment realize contactless switch control.

    ?

    Features

    ?

    1. Optical isolation between weak current part and strong current part

    2. Control signal and TTL logic interface

    3. The strong electric control switch is composed of thyristor and rectifier

    4. LED indicates working status

    5. Widely used in electrolysis, electroplating, electromagnetic vibration, electromagnetic magnets, DC power supplies, DC motors and other equipment for non-contact switch control

    ?

    Model meaning

    ?

    MJGZ-1 D2430A Model meaning
    M? Corporate logo: M: Mingxin
    JGZ Rectifier Solid State Relay
    -1 1: single phase 3: three phase
    D Control mode: D: DC 4-32VDC A: AC 80-250VAC
    twenty four Input load voltage: 24: 240VAC 44:440VAC, 66:660VAC
    30A Output rectified rated current: 30A 60A 100A 150A 200A 300A 450A

    ?

    Technical parameters

    ?

    one

    Mutually

    all

    flow

    solid

    state

    follow

    electricity

    device

    Input load supply voltage

    240VAC 440VAC?

    Output load rectified voltage

    Power supply voltage x0.9 (VDC)

    Output load current

    30A 60A 100A 150A200A 300A 450A

    control voltage

    3-32VDC/90-280VAC

    control current

    ≤25mA/DC or 12mA/AC

    Medium pressure resistance

    ≥2500V

    Insulation voltage

    ≥2500V

    Insulation resistance

    ≥100MΩ

    ambient temperature

    -25℃-+75℃

    Power frequency

    50-60Hz

    Installation method

    bolted

    weight

    480g

    ?

    temperature graph

    ?

    MJGZ rectifier solid state manual copy.jpg

    ?

    Overall dimensions and wiring diagram

    ?

    ?

    MJGZ-1 D24.jpg

    ?

    Module selection and precautions

    ?

    1. Depending on the load power, different current margins should be selected. The greater the power, the greater the current margin. Generally, the current capacity of the rectifier solid-state relay is 2-4 times the load current.

    2. The input and output terminals should be equipped with overvoltage and overcurrent protection measures. a. Overvoltage protection: The output end is connected in parallel with a freewheeling diode or varistor (when using 240V voltage, choose 470-500V, when using 440V voltage, choose 680-750V, when using 660V voltage, choose 1100-1200V) ; b. Overcurrent protection: The main circuit is connected in series with a quick disconnect switch or a quick fuse, and the value is 1.5 times the actual load current.

    3. Heat dissipation requirements: Depending on the current size, working mode, and environmental conditions of the selected rectifier solid-state relay, a corresponding equivalent radiator should be configured, and a fan or water cooling should be used for temperatures above 40A.

    4. Installation method: It is required that the contact between the product and the radiator must be flat and smooth, and a layer of thermally conductive silicone grease should be applied between the contact surfaces. Finally, the screws with flat washers and spring rings should be symmetrically tightened and fixed.