- solid state relay
- Circuit Board Solid State Relay
- Single phase solid state relay
- Industrial Solid State Relays
- Three-phase solid state relay
- Three-phase forward and reverse solid state relay
- Rail type three-phase solid state relay
- Industrial grade solid state relay module
- Tension controller
- Intelligent voltage regulation module
- Single and three-phase silicon controlled trigger
- heat sink
- Semiconductor module, rectifier bridge series
- time relay
- Digital display counter
- water level controller
- timer
- switching power supply
- S series switching power supply
- MS series switching power supply
- LRS series switching power supply
- D, T, Q multi-group series switching power supply
- DR rail series switching power supply
- NDR rail series switching power supply
- MDR rail series switching power supply
- HDR rail series switching power supply
- FY rainproof series switching power supply
- FS rainproof series switching power supply
- Foot switch
- Fan water pump controller
MS-200-24
Model meaning
?
MS-200-24 | Model meaning |
MS | Switching power supply development code: S: Basic type MS: Small size type LRS: Ultra-thin type |
200 | Rated power: 15W 25W 35W 50W 60W 75W 100W 120W 150W 200W 250W 350W 400W 500W 600W 1000W 1500W 2000W |
twenty four | Output DC voltage: 5V 12V 15V 24V 36V 48V |
?
Features
?
High performance/price ratio
Pressure resistant and high efficiency
Quality is close to that of European and American products
Input AC power for global use
Small size, light weight, easy to install
The output has multiple protections for overcurrent, overvoltage and short circuit.
Can output 1-4 different voltages at the same time
?
Technical parameters
?
model performance | MS-200-5 | MS-200-12 | MS-200-15 | MS-200-24 |
DC output voltage | 5V | 12V | 15V | 24V |
Output voltage tolerance (Note 2) | ±2% | ±1% | ±1% | ±1% |
Rated output current | 40A | 16.5A | 13.3A | 8.5A |
Output current range | 0-40A | 0-16.5A | 0-13.3A | 0-8.5A |
Ripple and noise (Note 3) | 180mVp-p | 120mVp-p | 120mVp-p | 120mVp-p |
Incoming line stability (Note 4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability (Note 5) | ±1% | ±0.5% | ±0.5% | ±0.5% |
DC output power | 200W | 200W | 200W | 200W |
efficiency | 75% | 79.5% | 80% | 81.5% |
DC voltage adjustable range | 4.75-5.5V | 10.8-13.2V | 13.5-16.5V | 21.6-26.4V |
Input voltage range | 85~132VAC/170~264VAC switch selects 47~63Hz; 248~370VDC | |||
Input current | 4.2A/115V 2.2A/230V | |||
Inrush current | Cold start current 35A/115V 60A/230V | |||
Leakage current | ||||
Overload protection | 105%~150% type: cut off output, reset: automatic recovery | |||
115%-135% reset: automatic recovery | ||||
high temperature protection | ? | |||
temperature coefficient | ±0.03%/℃(0~50℃) | |||
Start, rise, hold time | 200ms, 100ms, 20ms | |||
Earthquake resistance | 10~500Hz, 2G 10min./1 cycle, duration 60 minutes, each axis | |||
Pressure resistance | Input and output room: 1.5KVAC Input and shell: 1.5KVAC Output and shell: 0.5KVAC | |||
Isolation resistor | Input and output room, input and housing, output and housing: 500VDC/100M Ohms | |||
Working temperature, humidity | -10℃~+60℃ (refer to the output characteristics chart), 20%~90%RH | |||
Storage temperature and humidity | -20℃~+85℃, 10%~95%RH | |||
Overall dimensions | 199*110*50mm | |||
weight | 0.78Kg | |||
safety standards | 滿(mǎn)足 UL1012 REQUIREMENT (NOT APPLY FOR THE MARK) | |||
EMC standards | Meet FCC PART15JCONDUCTION CLASS A |
Note: 1. The test conditions for the above parameters are: 230V input, rated load, 25℃ 70% RH, temperature.
2. Tolerance: including setting tolerance, line stability, and load stability (Note 5).
3. Ripple test: Use A12" twisted pair at 20MHz, use 0.1uF&47uF capacitor short circuit for interruption.
4. Incoming line voltage stability test: The incoming line voltage is from the highest voltage to the highest voltage at full load.
5. Load stability test: load from 0% to 100%.
6. C3, 4, 41 must be removed
?
Dimensional drawing
?
?
?
?
Wiring location
?
Port 1.2: AC input
?
Port 3: Ground
?
Port 4: Secondary DC output V3
?
Port 5: Secondary DC output V2
?
Port 6: DC output COM
?
Port 7: Main DC output V1