亚洲春色中文字幕_免费99精品国产自在现??_—级v免费大片国产_日韩人妻无码aⅴ一区二区_婷婷丁香五月激情综合_久草综合精品zc_久久美女一级黄色电影_╳╳╳无尽性视频漫画_免费天堂无码成人AV电影在线观看_青青揄拍视频

Leave Your Message
*姓名不能為空!
* 留言內(nèi)容不能為空!
Product
Recommended products

MXA3300ZF

1. Use two single-phase thyristor chips and connect them in anti-parallel to form the output;

2. Vacuum + hydrogen charging protective welding technology;

3. The input signal is compatible with TTL and COMS digital logic circuits;

4. Optical isolation between input loop and output loop;

5. LED indicates working status;

6. The isolation voltage between the input terminal and the output terminal is ≥2500V;

7. A universal product with high cost performance, wide application and high reliability;

8. 100% load current aging test, passed European CE certification and international ISO9000 certification.

    Features

    ?

    1. Use two single-phase thyristor chips and connect them in anti-parallel to form the output;

    2. Vacuum + hydrogen charging protective welding technology;

    3. The input signal is compatible with TTL and COMS digital logic circuits;

    4. Optical isolation between input loop and output loop;

    5. LED indicates working status;

    6. The isolation voltage between the input terminal and the output terminal is ≥2500V;

    7. A universal product with high cost performance, wide application and high reliability;

    8. 100% load current aging test, passed European CE certification and international ISO9000 certification.

    ?

    Model meaning

    ?

    MXA3300ZF Model meaning
    MX Corporate logo: MX: Mingxin
    A Input control mode: D: DC 4-32VDC A: AC 80-250VAC
    3 Output load voltage: 3: 30-480VAC
    300 Output rated current value: 60A 80A 100A 120A 150A 200A 250A 300A 400A 500A 600A 1000A
    ZF Category: ZF:Industrial grade

    ?

    Technical parameters

    work

    Industry

    class

    solid

    state

    follow

    electricity

    device

    Model specifications

    MXA3250ZF、MXA3300ZF

    Control method

    AC controlled AC (AC-AC)

    Load current

    250A、300A

    load voltage

    30-480VAC

    control voltage

    80-250VAC

    control current

    AC≤15mA

    On-state leakage current

    ≤2mA

    On-state voltage reduction

    ≤1.5VAC

    Off state time

    ≤10mS

    Medium pressure resistance

    2500VAC

    Insulation resistance

    500MΩ/500VDC

    ambient temperature

    -30℃-+75℃

    Installation method

    bolted

    work instructions

    LED

    weight

    240g

    ?

    Overall dimensions

    MXA.jpg

    ?

    Product application

    ?

    MXA series industrial-grade solid-state relays use flame-retardant engineering plastic shells, epoxy resin potting, and threaded terminal connections. They have high structural strength, impact resistance, and strong vibration resistance. The input end drive current is small, and can be easily connected to computer terminals and Various digital program-controlled circuit interfaces are widely used in petrochemical equipment, food machinery, packaging machinery, textile machinery, CNC machine tools, plastic machinery, fitness equipment, entertainment facilities and other automation control fields.

    It is especially suitable for harsh environments such as corrosion, moisture, dustproof, explosion-proof requirements, and frequent switching situations.

    ?

    Safety precautions

    ?

    1. When the load current is higher than 10A, a radiator must be used or installed on a metal base plate with corresponding heat dissipation effect, and thermal silicone grease is applied between the solid state relay heat dissipation base plate and the mounting surface. Above 40A, a fan is used for forced cooling or water cooling.

    2. When used with inductive loads, high transient voltages and surge currents are applied to the output end, which may cause the solid-state relay to mislead or be damaged. It is usually necessary to connect a voltage control device with a specific clamping voltage to the output end, such as a bidirectional relay. Zener diode or varistor (MOV). It is recommended that the varistor be 1.6-1.9 times the rated voltage.

    3. When controlling a smaller load current load close to the minimum load current, a virtual load resistor must be connected in parallel to the load to reduce the output leakage current and produce a higher residual voltage on the load.

    4. In order to prevent the temperature rise of solid-state relays from exceeding the allowable value, the heat dissipation effect and installation location should be considered when designing and applying. When two or more solid-state relays are installed side by side, appropriate spacing should be left.

    5. The output terminals of multiple solid-state relays must not be used in parallel in an attempt to increase the output current. However, the output terminals can be used in series to accommodate higher operating voltages.

    6. When using multiple solid-state relays to share a control power supply, the input terminals can be used in series or in parallel.

    7. Please use this piece with caution for capacitive loads. Please choose a solid-state relay dedicated for capacitive loads.