- solid state relay
- Circuit Board Solid State Relay
- Single phase solid state relay
- Industrial Solid State Relays
- Three-phase solid state relay
- Three-phase forward and reverse solid state relay
- Rail type three-phase solid state relay
- Industrial grade solid state relay module
- Tension controller
- Intelligent voltage regulation module
- Single and three-phase silicon controlled trigger
- heat sink
- Semiconductor module, rectifier bridge series
- time relay
- Digital display counter
- water level controller
- timer
- switching power supply
- S series switching power supply
- MS series switching power supply
- LRS series switching power supply
- D, T, Q multi-group series switching power supply
- DR rail series switching power supply
- NDR rail series switching power supply
- MDR rail series switching power supply
- HDR rail series switching power supply
- FY rainproof series switching power supply
- FS rainproof series switching power supply
- Foot switch
- Fan water pump controller
Q-60B
Model meaning
?
Q-60-B | Model meaning |
Q? | Q: Four outputs |
60 | Rated power: 60W 120W 250W 320W |
B | Output DC voltage: B:5V,+12V,-5V,-12V, C:5V,+15V,-5V,-15V, D:5V,+12V,+24V,-12V, F:5V,+15V, +24V,-15V, |
?
Features
?
High performance-price ratio;
?
Pressure resistant and high efficiency;
?
The quality is close to that of European and American products;
?
Input AC power is applicable worldwide;
?
Small size, light weight, easy to install;
?
The output has multiple protections for overcurrent, overvoltage and short circuit: it can output 1-4 different voltages at the same time;
?
Technical parameters
?
model | Q-60B | Q-60D | ||||||||
output | DC output voltage | CH1:+5V | CH2:+12V | CH3:-5V | CH4:-12V | CH1:+5V | CH2:+12V | CH3:+24V | CH4:-12V | |
Output voltage tolerance | ±2% | ±6% | ±5% | ±5% | ±2% | ±6% | ±5% | ±5% | ||
Rated output current | 5.5A | 2A | 0.5A | 0.5A | 8A | 3A | 1.5A | 1A | ||
Output current range | 0.8~5.5A | 0.4~2A | 0~0.5A | 0~0.5A | 0.5~8A | 0.1~3A | 0.1~1.5A | 0~1A | ||
Output power | 60W | 60W | ||||||||
Ripple and noise | 80mvp-p | 120mvp-p | 80mvp-p | 120mvp-p | 80mvp-p | 120mvp-p | 80mvp-p | 120mvp-p | ||
Voltage adjustable range | CH1:-9%~+10% | |||||||||
enter | Input voltage range | 90~264VAC,127~373VDC | ||||||||
frequency | 47~63HZ | |||||||||
AC input current | 1.8A/115VAC,0.9A/230VAC | |||||||||
efficiency | 71% | 72% | ||||||||
Inrush current | Cold start current 25A/115VAC, 50A/230VAC | |||||||||
Leakage current |
| |||||||||
Protection characteristics | Overload protection | Overload protection starts at 110%~150% of rated output power | ||||||||
Protection mode: hiccup mode, automatically recovers after abnormal load conditions are removed | ||||||||||
Overvoltage protection | CH1:115%~135% | |||||||||
environment | Working temperature, humidity | -10℃~+60℃,20%~90%RH | ||||||||
Storage temperature and humidity | -20℃~+85℃, 10%~95%RH non-condensing | |||||||||
Earthquake resistance | 10~500HZ, 2G 10min/1 cycle, duration 60 minutes, each axis | |||||||||
Safety | Pressure resistance | Input and output room: 1.5KVAC Input and ground: 1.5KVAC Output and ground: 0.5KVAC | ||||||||
Insulation resistance | Between input and output, input and ground, output and ground: 100M ohms/500VDC | |||||||||
standard | safety standards | Comply with UL1012 | ||||||||
EMC standards | Comply with EN55022, CLASSA | |||||||||
other | size | 159*97*38mm (L*W*H) | ||||||||
Weight/Packaging | 0.5kg/45pcs/23.5kg/0.041 cubic meters | |||||||||
Remark | Unless otherwise specified, all parameters are measured at 230VAC voltage input, rated load and 25°C. | |||||||||
Ripple and noise voltages were measured on a 20MHZ bandwidth oscilloscope with 0.1μ and 47μ capacitors added to the ends of 12 feet of twisted pair cable. | ||||||||||
Tolerance is the sum of voltage setting error, voltage regulation, and current regulation. |
?
?