- solid state relay
- Circuit Board Solid State Relay
- Single phase solid state relay
- Industrial Solid State Relays
- Three-phase solid state relay
- Three-phase forward and reverse solid state relay
- Rail type three-phase solid state relay
- Industrial grade solid state relay module
- Tension controller
- Intelligent voltage regulation module
- Single and three-phase silicon controlled trigger
- heat sink
- Semiconductor module, rectifier bridge series
- time relay
- Digital display counter
- water level controller
- timer
- switching power supply
- S series switching power supply
- MS series switching power supply
- LRS series switching power supply
- D, T, Q multi-group series switching power supplies
- DR rail series switching power supply
- NDR rail series switching power supply
- MDR rail series switching power supply
- HDR rail series switching power supply
- FY rainproof series switching power supply
- FS rainproof series switching power supply
- Foot switch
- Fan water pump controller
S-1000
Model meaning
?
S-1000-24 | Model meaning |
S | Switching power supply development code: S: Basic type MS: Small size type LRS: Ultra-thin type |
1000 | Rated power: 15W 25W 35W 50W 60W 75W 100W 120W 150W 200W 250W 350W 400W 500W 600W 1000W 1500W 2000W |
twenty four | Output DC voltage: 5V 12V 15V 24V 36V 48V |
?
Features
?
High performance/price ratio
Pressure resistant and high efficiency
Quality is close to that of European and American products
Input AC power for global use
Small size, light weight, easy to install
The output has multiple protections for overcurrent, overvoltage and short circuit.
Can output 1-4 different voltages at the same time
?
Technical parameters
?
model performance | S-1000-12 | S-1000-13.5 | S-1000-15 | S-1000-24 | S-1000-27 | S-1000-(0-48) | |
DC output voltage | 12V | 13.5V | 15V | 24V | 27V | 1-48V | |
Output voltage tolerance | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |
Rated output current | 80A | 74A | 66A | 40A | 37A | 20A constant current | |
Output current range | 0~80A | 0~74A | 0~66A | 0~40A | 0~37A | 0~20A | |
Ripple and noise (Note 3) | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | |
Incoming line stability (Note 4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load stability (Note 5) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
DC output power | 1000W | 1000W | 990W | 1000.4W | 1000W | 1000W | |
efficiency | 84% | 84% | 85% | 85.50% | 86.50% | 87% | |
DC voltage adjustable range | 10~13.2V | 12~15V | 13.5~18V | 20~26.4V | 24~30V | 0~48V | |
Input voltage range | 190-240VAC/47~63Hz | ||||||
Input current | 7A/230V | ||||||
Inrush current | 50A/230V | ||||||
Leakage current |
| ||||||
Overload protection | 105%~150% type: Cut off output Reset: Automatic recovery | ||||||
Overvoltage protection | 13.8~16.2V | 15.5~18.2V | 18~21V | 18~21V | 27.6~32.4V | 31~36.5V | 57.6~67.2V |
High temperature protection | ≥70℃ cut off output (0~50v) | ||||||
temperature coefficient | ~+0.03%/℃(0-50℃) | ||||||
Start, rise, hold | 1.5s,50ms,20ms | ||||||
Earthquake resistance | 10-500Hz, 2G10min,/1 cycle, duration 60 minutes, each axis | ||||||
Pressure resistance | Input and output room: 1.5KvAC Input and housing: 1.5KvAC Output and housing: 0.5KvAC | ||||||
Isolation resistor | Input and output room: input and shell, output and shell: 500VDC/100MO | ||||||
Working temperature, humidity | ~-10℃~+60℃ (refer to the output characteristics chart), 20%~90%RH | ||||||
Storage temperature and humidity | ~-20℃~+85℃,10%-95%RH | ||||||
weight | 2.35kgs | ||||||
safety standards | Meets UL1950 requirements (does not apply for marking) | ||||||
EMC standards | CISPR22(EN55022),1EC1000-4,2,3.45,6,8,11EC1000-3-2 |
?
Dimensional drawing
?
?
?
?
?
Note: The test conditions for the above parameters 1 are: 230VAC input, rated load, 25C 70%Rh, humidity.
?
2. Tolerance: including setting tolerance, line stability, and load stability (Note 5).
?
3. Ripple test: Use "A12" twisted pair for 20MH, and use 0.1uF & 47uF capacitors for short circuit for interruption. 4. Incoming line voltage stability test: from the lowest voltage to the highest voltage on the incoming line at full load. 5. Load stability test: load from 0% to 100%
?
?