SSR- □□ AA

1. Bidirectional thyristor output, zero voltage on, zero current off;

2. Optical isolation between input loop and output loop;

3. The isolation voltage between the input terminal and the output terminal is 2500V;

4. 100% load current aging test, passed European CE certification, international ISO9000 certification, and domestic 3C certification.

    Features

    ?

    1. Bidirectional thyristor output, zero voltage on, zero current off;

    2. Optical isolation between input loop and output loop;

    3. The isolation voltage between the input terminal and the output terminal is 2500V;

    4. 100% load current aging test, passed European CE certification, international ISO9000 certification, and domestic 3C certification.

    ?

    Model meaning

    ?

    SSR-40AA-H Model meaning
    SSR solid state relay
    40 Output rated current value: 10A 25A 40A 60A 80A 100A
    AA

    Input control method:

    DA: DC controlled AC 3-32VDC/380VAC

    AA: AC control AC 80-250VAC/380VAC

    VA: Resistor type voltage regulating potentiometer 470KΩ-560K/380VAC

    DD: DC controlled DC 3-32VDC/60VDC/110VDC

    LA: Current type voltage regulation 4-20mA/230VAC

    DV: Pulse voltage regulation GT/250VAC

    -H

    Output voltage level: output voltage

    ①AC:Non:24-380VAC H:90-480VAC

    ②DC:Non:5-60VDC 5-110VDC H:5-250VDC

    ?

    Product application

    ?

    The SSR series single-phase solid state relay adopts flame-retardant engineering plastic shell, epoxy resin potting, and threaded terminal wiring. It has high structural strength, impact resistance, strong vibration resistance, and input terminal. The input end drive current is small and can be easily interfaced with computer terminals and various digital program-controlled circuits. It is widely used in petrochemical equipment, food machinery, packaging machinery, textile machinery, CNC machine tools, plastic machinery, fitness equipment, entertainment facilities and other automated controls. field.

    It is especially suitable for harsh environments such as corrosion, moisture, dustproof, explosion-proof requirements, and frequent switching situations. It is an updated replacement product for AC contactor.

    ?

    Technical parameters

    ?

    one

    Mutually

    pay

    flow

    solid

    state

    follow

    electricity

    device

    Product model

    SSR-10AA、SSR-25AA、SSR-40AA、SSR-50AA、SSR-60AA、SSR-80AA、SSR-100AA

    Control method

    AC controlled AC (AC-AC)

    Load current

    10A、25A、40A、50A、60A、80A、100A

    load voltage

    24-380VAC 、H:90-480VAC

    control voltage

    80-250VAC

    control current

    AC: 15mA

    On-state leakage current

    ≤2mA

    On-state voltage reduction

    ≤1.5VAC

    Off state time

    ≤10mS

    Medium pressure resistance

    2500VAC

    Insulation resistance

    500MΩ/500VDC

    ambient temperature

    -30℃-+75℃

    Installation method

    bolted

    work instructions

    LED

    weight

    132g

    ?

    ?

    Overall dimensions

    AA.jpg

    ?

    Safety precautions

    ?

    1. When the load current is higher than 10A, a radiator must be used or installed on a metal base plate with corresponding heat dissipation effect, and thermal silicone grease is applied between the solid state relay heat dissipation base plate and the mounting surface. Above 40A, a fan is used for forced cooling or water cooling.

    2. When used with AC inductive loads, high transient voltages and surge currents are applied to the output end, which may cause the solid-state relay to conduct or be damaged. It is usually necessary to connect a voltage control device with a specific clamping voltage to the output end, such as Bi-wire zener diode or varistor (MOV). It is recommended that the varistor be 1.6-1.9 times the rated voltage;

    3. When controlling a smaller current load close to the minimum load current, a virtual load resistor must be connected in parallel to the load to reduce the output leakage current and produce a higher residual voltage on the load.

    4. In order to prevent the temperature rise of solid-state relays from exceeding the allowable value, the heat dissipation effect and installation location should be considered when designing and applying. When two or more solid-state relays are installed side by side, appropriate spacing should be left.

    5. The output terminals of multiple solid-state relays must not be used in parallel in an attempt to increase the output current. However, the output terminals can be used in series to accommodate higher operating voltages.

    6. When using multiple solid-state relays to share a control power supply, the input terminals can be used in series or in parallel.

    7. Please use this piece with caution for capacitive loads. Please choose a solid-state relay dedicated for capacitive loads.