- solid state relay
- Circuit Board Solid State Relay
- Single phase solid state relay
- Industrial Solid State Relays
- Three-phase solid state relay
- Three-phase forward and reverse solid state relay
- Rail type three-phase solid state relay
- Industrial grade solid state relay module
- Tension controller
- Intelligent voltage regulation module
- Single and three-phase silicon controlled trigger
- heat sink
- Semiconductor module, rectifier bridge series
- time relay
- Digital display counter
- water level controller
- timer
- switching power supply
- S series switching power supply
- MS series switching power supply
- LRS series switching power supply
- D, T, Q multi-group series switching power supplies
- DR rail series switching power supply
- NDR rail series switching power supply
- MDR rail series switching power supply
- HDR rail series switching power supply
- FY rainproof series switching power supply
- FS rainproof series switching power supply
- Foot switch
- Fan water pump controller
SSR- □□ LA
Features
?
1. Bidirectional thyristor output, zero voltage on, zero current off;
2. Optical isolation between input loop and output loop;
3. The isolation voltage between the input terminal and the output terminal is 2500V;
4. 100% load current aging test, passed European CE certification, international ISO9000 certification, and domestic 3C certification.
?
Model meaning
?
SSR-40LA-H | Model meaning |
SSR | solid state relay |
40 | Output rated current value: 10A 25A 40A 60A 80A 100A |
THE | Input control method: DA: DC controlled AC 3-32VDC/380VAC AA: AC control AC 80-250VAC/380VAC VA: Resistor type voltage regulating potentiometer 470KΩ-560K/380VAC DD: DC controlled DC 3-32VDC/60VDC/110VDC LA: Current type voltage regulation 4-20mA/230VAC DV: Pulse voltage regulation GT/250VAC |
-H | Output voltage level: output voltage ①AC:Non:24-380VAC H:90-480VAC ②DC:Non:5-60VDC 5-110VDC H:5-250VDC |
?
Product application
?
The SSR series single-phase solid state relay adopts flame-retardant engineering plastic shell, epoxy resin potting, and threaded terminal wiring. It has high structural strength, impact resistance, strong vibration resistance, and input terminal. The input end drive current is small and can be easily interfaced with computer terminals and various digital program-controlled circuits. It is widely used in petrochemical equipment, food machinery, packaging machinery, textile machinery, CNC machine tools, plastic machinery, fitness equipment, entertainment facilities and other automated controls. field.
It is especially suitable for harsh environments such as corrosion, moisture, dustproof, explosion-proof requirements, and frequent switching situations. It is an updated replacement product for AC contactor.
?
Technical parameters
one Mutually electricity flow type pay flow solid state tune press device | Product model classification | SSR-10LA、SSR-25LA、SSR-40LA、SSR-50LA、SSR-60LA、SSR-80LA、SSR-100LA |
Control method | Current Mode Solid State Voltage Regulator | |
Load current | 10A、25A、40A、50A、60A、80A、100A | |
load voltage | 90~250VAC | |
Input control method | Random | |
control current | 4-20mA | |
On-state leakage current | ≤2mA | |
On-state voltage reduction | ≤1.5VAC | |
Off state time | / | |
Medium pressure resistance | 2000VAC | |
Insulation resistance | 500MΩ/500VDC | |
ambient temperature | -30℃-+75℃ | |
Installation method | bolted | |
work instructions | LED | |
weight | 132g |
?
?
?
Overall dimensions
?
?
Safety precautions
?
1. When the load current is higher than 10A, a radiator must be used or installed on a metal base plate with corresponding heat dissipation effect, and thermal silicone grease is applied between the solid state relay heat dissipation base plate and the mounting surface. Above 40A, a fan is used for forced cooling or water cooling.
2. When used with AC inductive loads, high transient voltages and surge currents are applied to the output end, which may cause the solid-state relay to conduct or be damaged. It is usually necessary to connect a voltage control device with a specific clamping voltage to the output end, such as Bi-wire zener diode or varistor (MOV). It is recommended that the varistor be 1.6-1.9 times the rated voltage;
3. When controlling a smaller current load close to the minimum load current, a virtual load resistor must be connected in parallel to the load to reduce the output leakage current and produce a higher residual voltage on the load.
4. In order to prevent the temperature rise of solid-state relays from exceeding the allowable value, the heat dissipation effect and installation location should be considered when designing and applying. When two or more solid-state relays are installed side by side, appropriate spacing should be left.
5. The output terminals of multiple solid-state relays must not be used in parallel in an attempt to increase the output current. However, the output terminals can be used in series to accommodate higher operating voltages.
6. When using multiple solid-state relays to share a control power supply, the input terminals can be used in series or in parallel.
7. Please use this piece with caution for capacitive loads. Please choose a solid-state relay dedicated for capacitive loads.