ZG3NC- □□ DL

1. Bidirectional thyristor output, zero voltage on, zero current off;

2. Optical isolation between input loop and output loop;

3. The isolation voltage between the input terminal and the output terminal is 2500V;

4. 100% load current aging test, passed European CE certification, international ISO9000 certification, and domestic 3C certification.

    Features

    ?

    1. The bidirectional thyristor output adopts a proportional zero-crossing control method, which turns the thyristor on or off when the AC zero crosses.

    2. The input end and output end are optically isolated, which is conducive to the control of weak current to strong current.

    3. The isolation voltage between the input terminal and the output terminal is 2500V;

    4. 100% load current aging test, passed European CE certification, international ISO9000 certification, and domestic 3C certification.

    5. Equipped with complete protective cover

    ?

    Model meaning

    ?

    ZG3NC-340DL Model meaning
    ZG3NC? ZG3NC: solid state relay ZG1NC: solid state voltage regulator
    3 Output load voltage: 2: 30-240VAC, 3: 24-480VAC 06:60VDC, 11:110VDC, 22:250VDC
    40 Output rated current: 10A 25A 40A 60A 80A 100A 120A
    DL

    Input control method:

    A: AC 80-250VAC

    B: DC 3-32VDC

    C: Adjustable resistance 470-560kΩ/2W

    DL: Current 4-20mA

    EL: Voltage 2-10VDC

    ?

    Product application

    ?

    The ZG3NC series solid-state voltage regulator adopts a flame-retardant engineering plastic shell, epoxy resin potting, and threaded terminal wiring. It has high structural strength, impact resistance, and strong vibration resistance. The input end drive current is small and can be easily connected to computer terminals and various A digital program-controlled circuit interface, widely used in petrochemical equipment, food machinery, packaging machinery, textile machinery, CNC machine tools, plastic machinery, fitness equipment, entertainment facilities and other automation control fields.

    It is especially suitable for use in harsh environments such as corrosion, moisture, dust-proof, and explosion-proof requirements, and in situations where frequent switching is required. It is an updated replacement product for AC contactors.

    ?

    Technical parameters

    one

    Mutually

    pay

    flow

    solid

    state

    tune

    press

    device

    Product model classification

    ??ZG3NC-210DL、ZG3NC-225DL、ZG3NC-240DL、ZG3NC-260DL、ZG3NC-280DL、ZG3NC-2100DL

    Control method

    DC controlled AC (DC-AC)

    Load current

    10A、25A、40A、60A、80A、100A

    load voltage

    24-230VAC

    control voltage

    \

    control current

    DC:4-20mA

    On-state leakage current

    ≤2mA

    On-state voltage reduction

    ≤1.5VAC

    Off state time

    ≤10mS

    Medium pressure resistance

    2500VAC

    Insulation resistance

    500MΩ/500VDC

    ambient temperature

    -30℃-+75℃

    Installation method

    bolted

    work instructions

    LED

    weight

    120g

    ?

    Overall dimensions

    ?

    DL.jpg

    ?

    Safety precautions

    ?

    1. When the load current is higher than 5A, a radiator must be used or installed on a metal base plate with corresponding heat dissipation effect. Thermal silicone grease should be applied between the solid state relay heat dissipation base plate and the mounting surface. Above 40A, a fan should be used for forced cooling or water cooling.

    2. When used with inductive loads, high transient voltages and surge currents are applied to the output end, which may cause the solid-state relay to mislead or be damaged. It is usually necessary to connect a voltage control device with a specific clamping voltage to the output end, such as a bidirectional relay. Zener diode or varistor (MOV). It is recommended that the varistor be 1.6-1.9 times the rated voltage.

    3. When controlling a smaller load current load close to the minimum load current, a virtual load resistor must be connected in parallel to the load to reduce the output leakage current and produce a higher residual voltage on the load.

    4. In order to prevent the temperature rise of solid-state relays from exceeding the allowable value, the heat dissipation effect and installation location should be considered when designing and applying. When two or more solid-state relays are installed side by side, appropriate spacing should be left.

    5. The output terminals of multiple solid-state relays must not be used in parallel in an attempt to increase the output current. However, the output terminals can be used in series to accommodate higher operating voltages.

    6. When using multiple solid-state relays to share a control power supply, the input terminals can be used in series or in parallel.

    7. Please use this piece with caution for capacitive loads. Please choose a solid-state relay dedicated for capacitive loads.